During typical operation, the LED’s on the bottom left hand corner of the keypad should NOT be
illuminated. The only LED that should light is the OPERATING LED, which should ash during
operation.
Panel Indicator LED’s
Power LED ON Red when Power is ON
OFF when power is OFF
SLEEP MODE Flashes every 1 second
Jack LED ON Red when Jack(s) are deployed
OFF when Jack(s) are stowed
Operating LED ON Red w/Auto Level or All Retract
OFF when keypad is idle or sleeping
Low Volatage LED ON Red when voltage is below 10.5 VDC
OFF when voltage is above 10.5 VDC
Engage Park Brake LED ON Red when park brake is not set
OFF when park brake is set
Ignition On LED ON Red when ignition is in the ON position
OFF when iginition is o
Excess Slope LED ON Red following an Auto Level attempt if
system cannot overcome slope
OFF when slope is not excessive
If the LOW VOLTAGE, or EXCESS SLOPE LED’s illuminate, you have an error condition that must be
corrected prior to operating the jacks.
Note: After an Auto Level process the operation light should turn off and the Excess Slope light should
be off. This indicates that the system has nished leveling and is within the .5-degree (approx. 7/16 inch
over 4 feet) front to rear and side to side leveling specication.
If the Excess Slope light is on, then the system was not able to complete the process within the
.5-degree specication. There are several possibilities to include but not limited to Low Voltage, jack(s)
running out of travel or system/component failure.