49
SWING GATES
8 Adjustment of operating parameters
If you need to modify the operating parameters (force, speedness
etc..):
1. Scroll down the parameters until you visualize the desire pa-
rameter (i.g. P032);
2. Confirm by pressing on the
key;
3. By pressing on
and , set up the desired value;
4. Confirm by pressing on the
key (display shows the param-
eters previously selected).
For the complete list of the “Operating Parameters” See
the table on page. 66.
9 Programming complete
WARNING At the end of the programming procedure, use the buttons and until the appearance of the symbol “----”, the
operator is now ready again for new manoeuvres.
To perform any “Advanced Programming” operations (cancellation of the remotes, configuration inputs, etc. ..), see
on page 63.