EasyManua.ls Logo

Dea NET24N - Page 67

Dea NET24N
208 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
65
PAR. PROCEDURE SETTABLE VALUES
PROGRAMMING PROCEDURES
Positioning of operator 1
Positioning of operator 2
Memorization of the motors’ stroke
Deletion of transmitters
Transmitters memorizing
Search and deletion of a transmitter
Loading of standard parameters: the list is up dated with factory settings
Lock access to programming
Unused parameter
Unused parameter
Unused parameter
Unused parameter
Unused parameter
Unused parameter
Unused parameter
PAR. PARAMETER DESCRIPTION SETTABLE VALUES
DEFAULT VALUES
(for different standards of installation)
sliding gate Swing gate overhead door barriers
INPUTS CONFIGURATION PARAMETERS
INPUT_3 selectioning input type • 000: IN3 type=free contact
• 001: IN3 type=constant resistance 8K2
(Contatto pulito) (Contatto pulito) (Contatto pulito) (Contatto pulito)
INPUT_1 operating selection • 000: NONE (unused parameter)
• 001: START (start)
• 002: PED. (pedestrian)
• 003: OPEN (separated open)
• 004: CLOSE (separated close)
• 005: OPEN_PM (man present open)
• 006: CLOSE_PM (man present close)
• 007: ELOCK-IN (electric-lock activation. See P062)
• 008: PHOTO 1 (photocell 1)
• 009: PHOTO 2 (photocell 2)
• 010: SAFETY (safety rib)
• 011: STOP (lock)
• 012: FCA1 (opening limit switches Mot1)
• 013: FCA2 (opening limit switchtes Mot2)
• 014: FCC1 (closing limit switches Mot1)
• 015: FCC2 (closing limit switches Mot2)
IN1
(START) (START) (START) (START)
INPUT_2 operating selection IN2
(PEDESTRIAN) (PEDESTRIAN) (PHOTO 1) (PHOTO 1)
INPUT_3 operating selection IN3
(SAFETY) (SAFETY) (SAFETY) (SAFETY)
INPUT_4 operating selection IN4
(PHOTO 1) (PHOTO 1) (STOP) (OPEN)
INPUT_5 operating selection IN5
(FCA1) (PHOTO 2) (NONE) (CLOSE)
INPUT_6 operating selection IN6
(FCC1) (STOP) (NONE) (STOP)
Allocation of CHANNEL 1 of remotes • 000: NONE (unused parameter)
• 001: START (start)
• 002: PEDESTRIAN (pedestrian)
• 003: OPEN (separated open)
• 004: CLOSED (separated close)
• 005: OPEN_PM (man present open)
• 006: CLOSED_PM (man present close)
• 007: ELOCK-IN (attivazione elettroserratura. Vedi P062)
CH1
(START) (START) (START) (START)
Allocation of CHANNEL 2 of remotes CH2
(NONE) (NONE) (NONE) (NONE)
Allocation of CHANNEL 3 of remotes CH3
(NONE) (NONE) (NONE) (NONE)
Allocation of CHANNEL 4 of remotes CH4
(NONE) (NONE) (NONE) (NONE)
Selection of type of remotes • 000: HCS fix-code
• 001: HCS rolling-code
• 002: Dip-switch