- 5 -
SPECIFICATIONS
CO Response Times:
70 PPM: 60-240 minutes,
150 PPM: 10-50 minutes,
400 PPM: 4-15 minutes,
Sensor Type:
Electrochemical
Operating Temperature and Humidity:
40
o
F to 100
o
F @ 10% to 95% RH
Audible Signal:
Buzzer Horn Sounds 85 dB at 10 feet
Visual Signal:
Green LED Indicates Power On
Alarm Red LED Indicates CO Alarm
Service Red LED Indicates Service Required
Detection Frequency:
Samples for CO every 10 seconds
LCD Display: Model CA6150
Digital Read-Out of Current and Highest CO Levels Detected
Peak Level Time Record (the total time Peak CO is detected within 10% of the
peak level)
Display Tolerance ±20% from 30 to 400 PPM @ 50% RH, 72°F ±
Sensor Life Monitor
Activates sensor expiration signal after ten years of operation
Factory Sealed Lithium Batteries
Two non-removable, non-replaceable lithium batteries for ten years of operation
under normal conditions
Electrical Rating:
6VDC