Dell EMC DP4400 - Install Network Validation Tool; Install the Rails

Dell EMC DP4400
17 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 1 IP address range assignments
IP Range
Allocation
Example Component Assigned Field
+0
192.0.2.1
vCenter VMware vCenter Server VM
+1
192.0.2.2
Target storage Management IP 1
+2
192.0.2.3
Target storage Backup IP 2
+3
192.0.2.4
Target storage Backup IP 3
+4
192.0.2.5
Backup application Server IP
+5
192.0.2.6
Backup application Avamar Proxy VM
+6
192.0.2.7
IDPA System Manager IDPA System Manager VM
+7
192.0.2.8
Reporting and Analytics Application Server Host VM
+8
192.0.2.9
Reporting and Analytics Datastore Server Host VM
+9
192.0.2.10
Search Index Master Node Host VM
+10
192.0.2.11
DD Cloud DR CDRA
(optional)
Data Domain Cloud Disaster
Recovery (DD Cloud DR) Cloud DR
Add-on (CDRA) virtual appliance
Note: IDPA is compatible with IPv4 enabled networks and does not support pure IPv6 or dual-
stack networks.
Install Network Validation Tool
The Network Validation Tool (NVT) for IDPA runs multiple automated tests to validate the network
configuration. You must run the NVT for IDPA from a system on the management network.
Before you install IDPA, network configuration must be completed for the datacenter. After the
network configuration is complete, you must install and run the Network Validation Tool to validate
the network configuration for a successful deployment of IDPA in the datacenter. To download the
NVT, and for more information about NVT, see https://help.psapps.emc.com/display/HELP/
Network+Validation+Tool+for+IDPA.
Install the rails
About this task
The rails are labeled left and right, and cannot be interchanged. The front side of each rail is
labeled Left Front or Right Front when the rail faces the cabinet front.
Procedure
1. Determine where to mount the system, and mark the location at the front and back of the
cabinet.
Note:
Install the left rail assembly first.
2. Fully extend the rear sliding bracket of the rail.
3. Position the rail end piece labeled Left Front facing inward and orient the rear end piece to
align with the holes on the rear cabinet flanges.
Dell EMC Integrated Data Protection Appliance DP4400 2.4 Hardware Installation Guide
5