Manage controller mode
NOTE: All existing congurations on the controller must be deleted before proceeding with a controller mode change. Once the
mode transition operation is conrmed, the process can take up to 5 seconds to complete; do not power o or reset the system
until the mode transition operation is complete.
1 Enter the Dell PERC 10 Conguration Utility. See Navigating to Dell PERC 10 conguration utility.
2
Click Main Menu > Controller Management > Advanced Controller Management > Manage Controller Mode.
3 Click Switch to Enhanced HBA mode or Switch to RAID mode.
CAUTION: Only use force switch controller mode as part of a controller replacement operation. Consult with technical
support for assistance.
4 Check the box to Conrm the controller mode change.
5 Click Yes to conrm the selection.
6 Click OK to acknowledge the change.
A reboot is required to complete the mode transition. Until this reboot is performed, avoid requesting any further changes. Prior to the
next reboot:
All conguration commands are blocked
Controller rmware ash is not allowed
Following the reboot, the mode transition will be complete and the controller will resume normal operation.
Changing prole using HII Conguration Utility
Perform the following steps to change the prole to HII conguration utility:
1 Enter the Dell PERC 10 Conguration Utility. See Navigating to Dell PERC 10 conguration utility.
2 Click Main Menu > Controller Management > Advanced Controller Management > Manage Controller Proles.
Current prole and prole properties are displayed.
3 Change prole using the Choose Prole option.
NOTE
: By default, eHBA mode only supports prole
23_PD240.
4 Select Set Prole.
Click Reboot.
NOTE
: For the changes to reect reboot is required.
NOTE: Prole change fails:
if new prole supports less number of drives than the number of drives in the current topology.
if background operations (rebuild, copy back, full initialization, Background Initialization, Patrol Read, CC) are active.
if background operations start after prole change but before the system is rebooted.