Troubleshooting
To get help with your Dell PowerEdge RAID Controller (PERC) 10 series of cards, you can contact your Dell Technical Service
representative or see Dell.com/support.
Topics:
Adapter at baseport not responding error message
BIOS disabled error message
Congured disks removed or not accessible error message
Dirty cache data error message
Discovery error message
Drive Conguration Changes Error Message
Windows operating system installation errors
Firmware fault state error message
Extra enclosure error message
Foreign conguration found error message
Foreign conguration not found in HII error message
Degraded state of virtual disks
Memory errors
Preserved Cache State
Security key errors
General issues
Physical disk issues
SMART errors
Replace member errors
Linux operating system errors
Disk carrier LED indicators
HII error messages
Adapter at baseport not responding error message
Error Message:
Adapter at Baseport xxxx is not responding, where xxxx is the baseport of the
controller.
Corrective Action: Contact Dell Technical Support.
BIOS disabled error message
Error Message:
BIOS Disabled. No Logical Drives Handled by BIOS.
Probable Cause: This warning message is displayed after you disable the ROM option in the conguration utility. When the ROM
option is disabled, the BIOS cannot boot to Int 13h and cannot provide the ability to boot from the virtual disk. Int
13h is an interrupt signal that supports numerous commands that are sent to the BIOS and then passed to the