Physical disk issues
Physical disk in failed state
Issue: One of the physical disks in the disk array is in the failed state.
Corrective Action: Update the PERC cards to the latest rmware available on Dell.com/support and replace the drive.
Unable to rebuild a fault tolerant virtual disk
Issue: Cannot rebuild a fault tolerant virtual disk. For more information, see the alert log for virtual disks.
Corrective Action: The replacement disk is too small or not compatible with the virtual disk. Replace the failed disk with a compatible
good physical disk with equal or greater capacity.
Fatal error or data corruption reported
Issue: Fatal error(s) or data corruption(s) are reported when accessing virtual disks.
Corrective Action: Contact Dell Technical Support.
Physical disk displayed as blocked
Issue:
One or more physical disks is displayed as Blocked and cannot be congured.
Corrective Action: Update the PERC cards to the latest rmware available on Dell.com/support. Replace the drive and ensure not to
use the blocked drive.
Multiple disks become inaccessible
Issue:
Rebuilding the physical disks after multiple disks become simultaneously inaccessible.
Corrective Action: Multiple physical disk errors in a single array typically indicate a failure in cabling or connection and could involve the
loss of data. You can recover the virtual disk after multiple physical disks become simultaneously inaccessible.
Perform the following steps to recover the virtual disk:
CAUTION: Follow the safety precautions to prevent electrostatic discharge.
1 Turn o the system, check cable connections, and reseat physical disks.
2 Ensure that all the disks are present in the enclosure.
3 Turn on the system and enter the HII Conguration Utility.
4 Import the foreign conguration.
5 Press <F> at the prompt to import the conguration, or press <C> to enter the HII Conguration Utility and either import or clear
the foreign conguration.
Troubleshooting
69