Number Severity Description/Recommended actions
Recommended actions:
• No action is required.
611 Error Email notication failed due to either:
• An unreachable SMTP server or a dierence between the sender and SMTP server domains.
• Improper conguration.
• Recommended actions:
– Verify the congured parameters and ask the recipients to conrm that they received the message.
Info. Email notication sent successfully. Please ask the recipients to conrm that they received the message.
• Verify the congured parameters and ask the recipients to conrm that they received the message.
612 Info. An alert condition was detected on an internal chassis SAS connector.
The event message species the location of the internal SAS connector in the chassis.
Recommended actions:
• No action is required.
613 Error An alert condition was detected on an IOM.
Recommended actions:
• Either install the indicated IOM or attempt to reseat it.
• If this does not resolve the issue, replace the IOM.
Warning An alert condition was detected on an IOM.
Recommended actions:
• If uninstalled, install the indicated IOM otherwise attempt to reseat it.
• If this does not resolve the issue, replace the IOM.
Info. Info An IOM was uninstalled.
Recommended actions:
• No action is required.
Resolved A previous Warning or Error condition for the IOM has been resolved.
Recommended actions:
• No action is required.
615 Info. A rebalance operation for an ADAPT disk group has started.
Recommended actions:
• No action is required.
616 Warning A rebalance operation for an ADAPT disk group has completed partially (because of drive failure).
Recommended actions:
• No action is required.
Info. A rebalance operation for an ADAPT disk group has completed.
138 Events and event messages