Table 29. Terminal emulator display settings
Parameter Value
Terminal emulation mode VT-100 or ANSI (for color support)
Font Terminal
Translations None
Columns 80
Table 30. Terminal emulator connection settings
Parameter Value
Connector COM3 (for example)
1,2
Baud rate 115,200
Data bits 8
Parity None
Parmaeter Value
Stop bits 1
Flow control None
1
Your server or laptop conguration determines which COM port is used for Disk Array USB Port.
2
Verify the appropriate COM port for use with the CLI.
3 In the terminal emulator, connect to controller A.
4 Press Enter to display the CLI prompt (#).
The CLI displays the system version, Management Controller version, and login prompt
a At the login prompt, enter the default user manage.
b Enter the default password !manage
If the default user or password—or both—have been changed for security reasons, enter the secure login credentials instead of the
defaults shown above.
Mini-USB Device Connection
Emulated serial port
Once attached to the controller module, the management computer should detect a new USB device. Using the Emulated Serial Port
interface, the ME4 Series controller presents a single serial port using a customer vendor ID and product ID. Eective presentation of the
emulated serial port assumes the management computer previously had terminal emulator installed. See also Supported host applications.
Serial port conguration is unnecessary.
IMPORTANT
: Certain operating systems require a device driver or special mode of operation to enable proper functioning of the
USB CLI port. See also Device Driver special operations mode.
142 Connecting through the CLI port using a serial cable