PCM OK
(Green)
Fan Fail
(Amber)
AC Fail
(Amber)
DC Fail
(Amber)
Status
On O O On PCM fan speed is outside acceptable limits
O On O O PCM fan has failed
O On On On PCM fault (above temperature, above voltage, above current)
O Blinking Blinking Blinking PCM rmware download is in progress
Ops panel LEDs
The Ops panel displays the aggregated status of all the modules. See 2U enclosure Ops panel. The Ops panel LEDs are dened in the
following table.
Table 12. Ops panel LEDs
System
Power
(Green/
Amber)
Module
Fault
(Amber)
Identity
(Blue)
LED display Associated LEDs /
Alarms
Status
On O O X 5V standby power present, overall power failed or
switched o
On On On On Ops panel power on (5s) test state
On O O X Power on, all functions good
On On X X PCM fault LEDs, fan
fault LEDs
Any PCM fault, fan fault, above or below
temperature
On On X X SBB module LEDs Any SBB module fault
On On X X No module LEDs Enclosure logical fault
On Blink X X Module status LED on
SBB module
Unknown (invalid or mixed) SBB module type
installed, I
2
C bus failure (inter-SBB
communications). EBOD VPD conguration error
On Blink X X PCM fault LEDs, fan
fault LEDs
Unknown (invalid or mixed) PCM type installed or
I
2
C bus failure (PCM communications)
X Blink Enclosure identication or invalid ID selected
X= Disregard
Actions:
• If the Ops panel Module Fault LED is on, check the module LEDs on the enclosure rear panel to narrow the fault to a CRU, a
connection, or both.
• Check the event log for specic information regarding the fault, and follow any Recommended Actions.
• If installing an IOM CRU:
– Remove and reinstall the IOM per the instructions in Removing an IOM.
– Check the event log for errors.
• If the CRU Fault LED is on, a fault condition is detected.
– Restart this controller from the partner controller using the ME Storage Manager or CLI.
– If the restart does not resolve the fault, remove the IOM and reinsert it.
34
Troubleshooting and problem solving