Number Severity Description/Recommended actions
Recommended actions:
Be sure to complete the trust procedure as documented in the CLI help for the trust command.
80 Info. The controller enabled or disabled the indicated parameters for one or more disks.
Recommended actions:
No action is required.
81 Info. The current controller has unkilled the partner controller. The other controller will restart.
Recommended actions:
No action is required.
83 Info. The partner controller is changing state (shutting down or restarting).
Recommended actions:
No action is required.
84 Warning The current controller that logged this event forced the partner controller to fail over.
Recommended actions:
Download the debug logs from your storage system and contact technical support. A service technician
can use the debug logs to determine the problem.
86 Info. Host-port or disk-channel parameters have been changed.
Recommended actions:
No action is required.
87 Warning The mirrored conguration retrieved by this controller from the partner controller has a bad cyclic redundancy
check (CRC). The local ash conguration will be used instead.
Recommended actions:
Restore the default conguration by using the restore defaults command, as described in the CLI
Reference Guide.
88 Warning The mirrored conguration retrieved by this controller from the partner controller is corrupt. The local ash
conguration will be used instead.
Recommended actions:
Restore the default conguration by using the restore defaults command, as described in the CLI
Reference Guide.
89 Warning The mirrored conguration retrieved by this controller from the partner controller has a conguration level that
is too high for the rmware in this controller to process. The local ash conguration will be used instead.
Recommended actions:
The current controller that logged this event probably has down-level rmware. Update the rmware in
the down-level controller. Both controllers should have the same rmware versions.
When the problem is resolved, event 20 is logged.
90 Info. The partner controller does not have a mirrored conguration image for the current controller, so the current
controller's local ash conguration is being used.
This event is expected if the other controller is new or its conguration has been changed.
90 Events and event messages