Number Severity Description/Recommended actions
Recommended actions:
No action is required.
91 Error In a testing environment, the diagnostic that checks hardware reset signals between controllers in Active-
Active mode failed.
Recommended actions:
Perform failure analysis.
95 Error Both controllers in an Active-Active conguration have the same serial number. Non-unique serial numbers can
cause system problems. For example, WWNs are determined by serial number.
Recommended actions:
Remove one of the controller modules and insert a replacement, then return the removed module to be
reprogrammed.
96 Info. Pending conguration changes that take eect at startup were ignored because customer data might be
present in cache.
Recommended actions:
If the requested conguration changes did not occur, make the changes again and then use a user-
interface command to shut down the Storage Controller and then restart it.
103 Info. The name has been changed for the indicated volume.
Recommended actions:
No action is required.
104 Info. The size has been changed for the indicated volume.
Recommended actions:
No action is required.
105 Info. The default LUN (logical unit number) has been changed for the indicated volume.
Recommended actions:
No action is required.
106 Info. The indicated volume has been added to the indicated pool.
Recommended actions:
No action is required.
107 Error A serious error has been detected by the controller. In a single-controller conguration, the controller will
restart automatically. In an Active-Active conguration, the partner controller will kill the controller that
experienced the error.
Recommended actions:
Download the debug logs from your storage system and contact technical support. A service technician
can use the debug logs to determine the problem.
108 Info. The indicated volume has been deleted from the indicated pool.
Recommended actions:
No action is required.