Gaseous contamination Specications
NOTE: Maximum corrosive contaminant levels measured at ≤50% relative humidity.
Maximum vibration specications
Table 24. Maximum vibration specications
Maximum vibration Specications
Operating 0.26 Grms at 5 Hz to 350 Hz (all operation orientations).
Storage 1.88 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested).
Maximum shock specications
Table 25. Maximum shock specications
Maximum shock Specications
Operating 24 executed shock pulses 6 G in the positive and negative x, y, z
axis for up to 11 ms (four pulses on each side of the system).
Storage Six consecutively executed shock pulses of 71 G in the positive and
negative x, y, z axes for up to 2 ms (one pulse on each side of the
system).
Maximum altitude specications
Table 26. Maximum altitude
specications
Maximum altitude Specications
Operating 3048 m (10,000 ft)
Storage 12,000 m (39,370 ft)
Fresh Air Operation
Fresh Air operation restrictions
• Processors with a TDP greater than 105 W are not supported
• Support for processors of 85 W and below without PERC restrictions
• 3.5-inch drive conguration is not supported
• 114-mm heat sink is required for the processor in CPU1 socket
• Kerby-at OCP is not supported
36
Technical specications