Removing a processor and heat sink module
Prerequisites
WARNING: The heat sink may be hot to touch for some time after the system is powered o. Allow the heat sink to cool before
removing it.
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in After working inside your enclosure.
3 Remove the sled from the enclosure.
4 Remove the air shroud.
5 If installed, disconnect the fabric cable from the fabric processor.
NOTE: The process to remove a processor heat sink module (PHM) is identical for a fabric and a nonfabric processor.
Steps
1 Using a Torx #T30 screwdriver, loosen the screws on the heat sink in the order mentioned below:
a Loosen the rst screw three turns.
b Loosen the second screw completely.
c Return to the rst screw and loosen it completely.
2 Pushing both blue retention clips simultaneously, lift the PHM processor and heat sink module
3 Set the PHM aside with the processor side facing up.
Installing and removing enclosure components
83