Figure 30. Group topology
Dene networks
Prerequisites
Networks or subnets should be dened to meet the Cloud Foundation requirements. The prerequisites to dene networks are as follows:
1 Create chassis groups
2 Cloud Foundation management network
3 vMotion network
4 vSAN network
5 VXLAN network
6 Uplink1 network
7 Uplink2 network
To dene networks using the OME-Modular console, perform the following steps:
Steps
1 Open the OME-M console.
2 From the Conguration menu, click Networks.
3 In the Network pane, click Dene.
4 In the Dene Network window, complete the following:
a Enter the name of the network.
b Optionally, enter the description in the DESCRIPTION box.
c Enter the value 1611 in the VLAN ID box.
d From the Network Type list, select General Purpose (Bronze).
e Click Finish.
5 Repeat steps 1-4 to create the remaining ve VLANs and any other VLANs required.
A sample completed conguration is shown in the following gure:
Figure 31. VLAN conguration
56
SmartFabric network conguration