EasyManua.ls Logo

Dell EMC PowerEdge R540 - Page 13

Dell EMC PowerEdge R540
184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 4. Status LED indicators and descriptions
Icon Description Condition Corrective action
Drive
indicator
The indicator turns solid amber if
there is a drive error.
Check the System Event Log to determine if the drive has an error.
Run the appropriate Online Diagnostics test. Restart the system and
run embedded diagnostics (ePSA).
If the drives are congured in a RAID array, restart the system, and
enter the host adapter conguration utility program.
Temperature
indicator
The indicator turns solid amber if
the system experiences a thermal
error (for example, the ambient
temperature is out of range or
there is a fan failure).
Ensure that none of the following conditions exist:
A cooling fan has been removed or has failed.
Ambient temperature is too high.
External airow is obstructed.
If the problem persists, see Getting help.
Electrical
indicator
The indicator turns solid amber if
the system experiences an
electrical error (for example,
voltage out of range, or a failed
power supply unit (PSU) or voltage
regulator).
Check the System Event Log or system messages for the specic issue. If
it is due to a problem with the PSU, check the LED on the PSU. Reseat the
PSU.
If the problem persists, see Getting help.
Memory
indicator
The indicator turns solid amber if a
memory error occurs.
Check the System Event Log or system messages for the location of the
failed memory. Reseat the memory module.
If the problem persists, see Getting help.
PCIe
indicator
The indicator turns solid amber if a
PCIe card experiences an error.
Restart the system. Update any required drivers for the PCIe card. Reinstall
the card.
If the problem persists, see Getting help.
NOTE: For more information about the supported PCIe cards, see
Expansion card installation guidelines.
System health and system ID indicator codes
The system health and system ID indicator is located on the left control panel of your system.
Figure 6. System health and system ID indicators