Tape Drives
The R740 and R740xd do not support internal tape drives. However, external tape backup devices will be supported on both R740 and
R740xd.
Supported external tape drives:
• External RD1000 USB
• External LTO-5, LTO-6, LTO-7 and 6 Gb SAS tape drives
• 114X rack mount chassis with LTO-5, LTO-6, and LTO-7 6Gb SAS tape drives
• TL1000 with LTO-5, LTO-6, and LTO-7 6 Gb SAS tape drives
• TL2000 with LTO-5, LTO-6, and LTO-7 6 Gb SAS tape drives
• TL4000 with LTO-5, LTO-6, and LTO-7 6 Gb SAS tape drives
• TL4000 with LTO-5, LTO-6, and LTO-7 8Gb FC tape drives
• ML6000 with LTO-5, LTO-6, 6 Gb SAS tape drives
• ML6000 with LTO-5, LTO-6, LTO-7 8Gb FC tape drives
Boot Optimized Storage Subsystem (BOSS)
The BOSS is oered as a means of booting R740/R740xd systems to a full OS mode when,
• target OS is a full OS and not hypervisor that may supported best by IDSDM
• the user does not wish to trade o standard hot plug drive slots for OS install
The Hardware RAID BOSS is a RAID controller with a limited feature set for the purpose of boot up to a full OS drive. The BOSS RAID
controller presents M.2 SATA-only Solid State drives (SSD) as either Non-RAID disks or a single RAID1 volume conguration.
Figure 13. Boot Optimized Storage Subsystem (BOSS)
Table 13. BOSS RAID controller features
Function/Feature Supported
Stripe size supported 64k
Conguration (HII) Yes
Full initialization No
Fast initialization Yes
Storage 39