7 On the System Setup Main Menu screen, click System BIOS > System Security Settings.
8 Select the TPM Advanced Settings option.
9 From the TPM2 Algorithm Selection option, select SHA256, then go back to System Security Settings screen.
10 On the System Security Settings screen, from the Intel TXT option, select On.
11 Save the settings.
12 Restart your system.
Control panel
Control panel details
Your system supports:
Left control panel: Contains status LEDs, system ID button, and iDRAC Quick Sync 2 (optional).
Right control panel: Contains power button, USB 2.0 port, VGA port micro USB for iDRAC Direct, and status LED for iDRAC Direct.
Removing the left control panel
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3 Remove the cooling fan assembly.
4 Remove the air shroud
Steps
1 Pull the cable latch and disconnect the control panel cable from the system board connector.
2 Using a Phillips #1 screwdriver, remove the screws to remove the cable cover, which secure the lest control panel and cable tube to
the system.
3 Holding the control panel and cable tube by its sides, remove the control panel and cable tube away from the system.
Installing and removing system components