EasyManua.ls Logo

Dell EMC PowerEdge R740xd2 - Optional Internal USB Memory Key; Replacing the Optional Internal USB Memory Key

Dell EMC PowerEdge R740xd2
197 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10 Enter the correct time and date in the System Setup Time and Date elds.
11 Exit the System Setup.
Optional internal USB memory key
NOTE: To locate the internal USB port on the system board, see the System board jumpers and connectors section.
Replacing the optional internal USB memory key
Prerequisites
CAUTION: To avoid interference with other components in the server, the maximum permissible dimensions of the USB memory
key are 15.9 mm wide x 57.15 mm long x 7.9 mm high.
1 Follow the safety guidelines listed in Safety instructions.
2 Power o the system and all attached peripherals.
3 Disconnect the system from the electrical outlet, and disconnect the peripherals.
4 Ensure that all internal cables are routed correctly and connected, and no tools or extra parts are left inside the system.
5 Open the drive bays, remove all drives, and then close the drive bays.
6 Remove the power supply units.
7 Remove the system from the rack and place it on an ESD work bench. For more information, see the Rail Installation Guide available at
www.dell.com/poweredgemanuals.
8 Remove the system cover.
9 Remove the air shroud.
10 If installed, remove the low prole expansion card riser.
Steps
1 Locate the USB port or USB memory key on the system board.
To locate the USB port, see the jumpers and connectors.
2 If installed, remove the USB memory key from the USB port.
Figure 116. Removing the internal USB memory key
1
USB memory key 2 USB port
3 Insert the replacement USB memory key into the USB port.
142
Installing and removing system components

Table of Contents

Other manuals for Dell EMC PowerEdge R740xd2

Related product manuals