Figure 24. Removing air shroud for system with rear drive conguration
Next step
Replace the air shroud.
Installing the air shroud
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Power o the system and all attached peripherals.
3 Disconnect the system from the electrical outlet, and disconnect the peripherals.
4 Ensure that all internal cables are routed correctly and connected, and no tools or extra parts are left inside the system.
5 Open the drive bays, remove all drives, and then close the drive bays.
6 Remove the power supply units.
7 Remove the system from the rack and place it on an ESD work bench. For more information, see the Rail Installation Guide available at
www.dell.com/poweredgemanuals.
8 Remove the system cover.
9 If installed, remove the buttery riser.
Steps
1 Align the slots on the air shroud with the guide pin on the system.
NOTE
: Route the cable properly to prevent the cable from being pinched or crimped.
2 Lower the air shroud into the system until it is rmly seated.