Figure 30. Installing internal PERC riser
Next steps
1 Connect the cables to the backplane and then route the cables to the cable guiding latch and close the latch.
2 If removed, install the rear drive cage.
3 Install the air shroud.
4 Install the system cover.
5 Place the system into the rack. For more information, see the Rail Installation Guide available at www.dell.com/poweredgemanuals.
6 Open the drive bays, install all drives, and then close the drive bays.
7 Install the power supply units.
8 Follow the procedure listed in After working inside your system.
Removing the PERC card from the internal PERC riser
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Power o the system and all attached peripherals.
3 Disconnect the system from the electrical outlet, and disconnect the peripherals.
4 Open the drive bays, remove all drives, and then close the drive bays.
5 Remove the power supply units.
6 Remove the system from the rack and place it on an ESD work bench. For more information, see the Rail Installation Guide available at
www.dell.com/poweredgemanuals.
7 Remove the system cover.
8 Remove the air shroud.
9 If installed, remove the rear drive cage.
10 Remove the internal PERC riser.
58
Installing and removing system components