EasyManua.ls Logo

Dell EMC PowerEdge R740xd2 - Cooling Fans; Removing the Cooling Fan

Dell EMC PowerEdge R740xd2
197 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cooling fans
Removing the cooling fan
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Power o the system and all attached peripherals.
3 Disconnect the system from the electrical outlet, and disconnect the peripherals.
4 Open the drive bays, remove all drives, and then close the drive bays.
5 Remove the power supply units.
6 Remove the system from the rack and place it on an ESD work bench. For more information, see the Rail Installation Guide available at
www.dell.com/poweredgemanuals.
7 Remove the system cover.
8 Remove the air shroud.
9 Remove the internal PERC riser.
10 Move the cables out of the way to access the cooling fan cable connector on the system board.
Steps
1 Press the tabs on the fan cable connector and disconnect the cable from the system board.
2 Remove the cable from the cable retention tabs.
3 Press the blue release tab and lift the cooling fan from the cooling fan cage.
NOTE
: If removing cooling fan 1, remove the fan cable connector from the power interposer board (PIB).
Installing and removing system components 61

Table of Contents

Other manuals for Dell EMC PowerEdge R740xd2

Related product manuals