Next steps
1 Install the internal PERC riser.
2 Install the air shroud.
3 Install the system cover.
4 Place the system into the rack. For more information, see the Rail Installation Guide available at www.dell.com/poweredgemanuals.
5 Open the drive bays, install all drives, and then close the drive bays.
6 Install the power supply units.
7 Follow the procedure listed in After working inside your system.
Intrusion switch
Removing the intrusion switch
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Power o the system and all attached peripherals.
3 Disconnect the system from the electrical outlet, and disconnect the peripherals.
4 Open the drive bays, remove all drives, and then close the drive bays.
5 Remove the power supply units.
6 Remove the system from the rack and place it on an ESD work bench. For more information, see the Rail Installation Guide available at
www.dell.com/poweredgemanuals.
7 Remove the system cover.
8 Remove the air shroud.
9 Remove the internal PERC riser.
Steps
1 Disconnect and remove the intrusion switch cable from the system board.
NOTE
: Observe the routing of the cable as you remove it from the system. Route the cable properly when you replace it
to prevent the cable from being pinched or crimped.
2 Using a plastic scribe, slide the intrusion switch from the slot.
Installing and removing system components
65