EasyManua.ls Logo

Dell EMC PowerEdge R740xd2 - Intrusion Switch; Removing the Intrusion Switch

Dell EMC PowerEdge R740xd2
197 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Next steps
1 Install the internal PERC riser.
2 Install the air shroud.
3 Install the system cover.
4 Place the system into the rack. For more information, see the Rail Installation Guide available at www.dell.com/poweredgemanuals.
5 Open the drive bays, install all drives, and then close the drive bays.
6 Install the power supply units.
7 Follow the procedure listed in After working inside your system.
Intrusion switch
Removing the intrusion switch
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Power o the system and all attached peripherals.
3 Disconnect the system from the electrical outlet, and disconnect the peripherals.
4 Open the drive bays, remove all drives, and then close the drive bays.
5 Remove the power supply units.
6 Remove the system from the rack and place it on an ESD work bench. For more information, see the Rail Installation Guide available at
www.dell.com/poweredgemanuals.
7 Remove the system cover.
8 Remove the air shroud.
9 Remove the internal PERC riser.
Steps
1 Disconnect and remove the intrusion switch cable from the system board.
NOTE
: Observe the routing of the cable as you remove it from the system. Route the cable properly when you replace it
to prevent the cable from being pinched or crimped.
2 Using a plastic scribe, slide the intrusion switch from the slot.