EasyManua.ls Logo

Dell EMC PowerEdge R740xd2 - Drives; Removing a Drive Blank

Dell EMC PowerEdge R740xd2
197 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 40. Closing drive bays
2 If required, lock the drive bay lock located above left release latch, by pushing it down.
Next step
If removed, install front bezel.
Drives
Removing a drive blank
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 If installed, remove the front bezel.
CAUTION
: To maintain proper system cooling, drive blanks must be installed in all empty drive slots.
CAUTION: Mixing drive blanks from previous generations of PowerEdge servers is not supported.
Step
Press the release button, and slide the drive blank out of the drive slot.
Installing and removing system components