EasyManua.ls Logo

Dell EMC PowerEdge R7425 - Page 183

Dell EMC PowerEdge R7425
193 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
c Update the BIOS and iDRAC versions.
d Re-enable the Trusted Platform Module (TPM). For more information, see the Upgrading the Trusted Platform Module section.
5 Import your new or existing iDRAC Enterprise license.
For more information, see Integrated Dell Remote Access Controller User's Guide, at Dell.com/idracmanuals.
Entering the system Service Tag by using System Setup
If Easy Restore fails to restore the Service Tag, use System Setup to enter the Service Tag.
1 Turn on the
system.
2 Press F2 to enter System Setup.
3 Click
Service Tag Settings.
4 Enter the Service Tag.
NOTE
: You can enter the Service Tag only when the Service Tag eld is empty. Ensure that you enter the correct Service
Tag. After the Service Tag is entered, it cannot be updated or changed.
5 Click
Ok.
6 Import your new or existing iDRAC Enterprise license.
For more information, see the Integrated Dell Remote Access Controller User's Guide at Dell.com/idracmanuals.
Restoring the Service Tag by using the Easy Restore feature
By using the Easy Restore feature, you can restore your Service Tag, license, UEFI con
guration, and the system conguration data after
replacing the system board. All data is automatically backed up in a backup ash device. If BIOS detects a new system board and the
Service Tag is dierent in the backup ash device, BIOS prompts the user to restore the backup information.
1 Turn on the system.
If BIOS detects a new system board, and if the Service Tag is present in the backup ash de
vice, BIOS displays the Service Tag, the
status of the license, and the UEFI Diagnostics version.
2 Perform one of the following steps:
Press
Y to restore the Service Tag, license, and diagnostics information.
Press
N to navigate to the Dell Lifecycle Controller based restore options.
Press F10 to restore data from a previously created Hardware Server Pr
ole.
After the restore process is complete, BIOS prompts to restore the system conguration data.
NOTE: If restoring the Service Tag is successful, you can check the Service Tag information in the System Information
screen and compare it with the Service Tag on the system.
3 Perform one of the following steps:
Press
Y to restore the system conguration data.
Press
N to use the default conguration settings.
After the restore process is complete, the system restarts.
Manually update the Service Tag
After replacing a system board, if Easy Restore fails, follow this process to manually enter the Service Tag, using System Setup.
About this task
If you know the system service tag, use the
System Setup menu to enter the service tag.
Steps
1 Turn on the system.
2 To enter the System Setup, press F2.
Installing and removing system components 183

Table of Contents

Other manuals for Dell EMC PowerEdge R7425

Related product manuals