Table 68. Thermal restriction matrix for V100S GPU Card (continued)
Drive Configuration
type
8 x 3.5-inch drives 12 x 3.5-inch
drives
12 x 3.5-inch
drives
24 x 2.5-inch
drives
12 x 2.5-inch
drives SAS +
12 x 2.5-inch
drives NVMe
24 x 2.5-inch
drives NVMe
Slot 2/Slot
3 Slot 4/
Slot 5
N/A N/A N/A HPR Fan 1U
HPR HSK
N/A N/A
NOTE: 8 x 3.5-inch drives chassis do not support AUX power cable, and therefore do not support V100S GPU card .
Table 69. Processor support matrix
TDP (W) Fan type Fan type (8
x 3.5-
inch/24 x
2.5-inch)
HSK Type(8 x
3.5-inch/24 x
2.5/12x2.5-
inchSAS+ 12 x
2.5-
inchNVMe/
24x2.5-
inchNVMe)
HSK Type(12
x 3.5-inch)
HSK Type(12 x
3.5-inch+Rear
2 x 3.5-inch)
ASHRAE A3
support
ASHRAE A4
support
280 HPR Fan HPR Fan 1U HPR NA 2U HPR No No
240 HPR Fan HPR Fan 1U HPR 1U HPR 2U HPR No No
225 HPR Fan HPR Fan 1U HPR 1U HPR 2U HPR No No
200 HPR Fan STD Fan 1U HPR 1U HPR 2U HPR No No
180 HPR Fan STD Fan 1U HPR 1U HPR 2U HPR No No
155 HPR Fan STD Fan 1U HPR 1U HPR 2U HPR Yes No
120 HPR Fan STD Fan 1U HPR 1U HPR 2U HPR Yes Yes
NOTE: HPR fan is required for T4 GPU, V100S GPU, NVMe, and Double wide FPGA supporting.
NOTE: NVMe configuration with drive install/Nvidia T4/ Double Width FPGA
NOTE: Except for 8 x 3.5-inch/24 x 2.5-inch(without NVMe), all other configurations have only high-performance fan
type.
NOTE: 12 x 3.5-inch does not support 280 W processor.
NOTE: Need DIMM blank support for Evans HDD (RJT6H, 7KT9W, PY7WD, CNXPV, WGXDC, V308G, 3JTD3, 39XRY) in
12 x 3.5-inch drive configuration.
Other thermal restrictions
Mellanox CX5 with QSFP28 is restricted to slot 4 and slot 5 in no rear drive configuration. Non-Dell qualified cables are not supported.
Mellanox CX6 with QSFP56 (Mellanox MFS1S00) is restricted to slot 4 and slot 5 in no rear drive configuration. Non-Dell qualified
cables are not supported.
Solarflare XtremeScale X2522-25G adapter is restricted to slot 4 and slot 5 in no rear drive configuration.
750 GB PCIe SSD Adapter (P4800) by Intel is restricted to slot 4 and slot 5 in no rear drive configuration.
25 G LOM riser is not supported with 128 G LRDIMM or higher on 12 x 3.5-inch drives configuration.
DIMM blank is required at 12 x 3.5-inch and 12 x 3.5-inch + 2 x 3.5-inch (rear) storage configuration.
Particulate and gaseous contamination specifications
The following table defines the limitations that help avoid any damages to the IT equipment and/or, or both failure from particulate and
gaseous contamination. If the levels of particulate or gaseous pollution exceed the specified limitations and results in equipment damage or
failure, you must rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.
156
Technical specifications