Figure 65. Installing the heat sink
5. Return to the first screw to tighten it.
Next steps
1. Install the air shroud.
2. Follow the procedure listed in After working inside your system on page 44.
Expansion cards and expansion card risers
NOTE:
A system event entry is logged in the iDRAC Lifecycle Controller if an expansion card riser is not supported or
missing. It does not prevent your system from turning on. However, if a F1/F2 pause occurs with an error message, see
Troubleshooting expansion cards
section in the
Dell EMC PowerEdge Servers Troubleshooting Guide
at www.dell.com/
poweredgemanuals.
Expansion card installation guidelines
The following table describes the supported expansion cards:
Table 43. Expansion card riser configurations
Expansion card riser PCIe slots on the riser Processor
connection
Height Length Slot
width
Riser-1B (2U riser) Slot 2 Processor 1 Full Height Full Length x16
Riser-1B (2U riser) Slot 3 Processor 1 Full Height Full Length x16
Riser-1A (low profile
riser right)
Slot 2 Processor 1 Low Profile Half Length x16
Riser-2 (low profile riser
left)
Slot 3 Processor 1 Low Profile Half Length x16
NOTE: The expansion-card slots are not hot-swappable.