EasyManua.ls Logo

Dell EMC PowerEdge R940xa - Power Supply Units

Dell EMC PowerEdge R940xa
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Power supply units
Energy Smart power supplies have intelligent features, such as the ability to dynamically optimize eciency while maintaining
availability and redundancy. Also featured are enhanced power-consumption reduction technologies, such as high-eciency power
conversion and advanced thermal-management techniques, and embedded power-management features, including high-accuracy
power monitoring
The table below shows the power supply unit options that are available for R940xa:
Wattage Frequency Voltage Class Heat dissipation
1100W DC - '-48--60Vdc/32A N/A 4416 BTU/hr
1100W 50/60Hz 100-240Vac/12-6.5A Platinum 4100 BTU/hr
1100W Mix Mode/
HVDC(China and Japan
Only)
50/60Hz 100-240Vac/12A-6.5A Platinum 4100 BTU/hr
N/A 200-380Vdc/6.4A-3.2A N/A 4100 BTU/hr
1600W 50/60Hz 100-240Vac/10A Platinum 6000 BTU/hr
2000W 50/60Hz 100-240Vac/11.5A Platinum 7500 BTU/hr
2400W 50/60Hz 100-240Vac/16A Platinum 9000 BTU/hr
NOTE: If a system with AC 1100 W PSUs operate at low line 100-120 Vac, then the power rating per PSU is derated to
1050 W.
NOTE: If a system with AC 1600 W PSUs operate at low line 100-120 Vac, then the power rating per PSU is derated to
800 W.
NOTE: If a system with AC 2000 W PSUs operate at low line 100-120 Vac, then the power rating per PSU is derated to
1000 W.
The PowerEdge R940xa support up to 2 AC or DC power supplies with 1+1 redundancy, auto sensing, and auto-switching capability.
If two PSUs are present during POST, a comparison is made between the wattage capacities of the PSUs. In the event that the PSU
wattages don't match, the larger of the two PSU's is enabled. Also, there is a PSU mismatch warning displayed in BIOS, iDRAC, or on
the System LCD.
If a second PSU is added at run-time, in order for that particular PSU to be enabled, the wattage capacity of the rst PSU must
equal the second PSU. Otherwise, the PSU will be agged as unmatched in iDRAC and the second PSU will not be enabled
Dell EMC PSUs have achieved Platinum and Titanium eciency levels as shown in the table below:
Table 18. PSU eciency level
Form factor Eciency target by load
Output Class 10 20 50 100
Redundant
86mm
1100W AC Platinum 89.00% 93.00% 94.50% 92.00%
1100W DC Gold 0.00% 88.00% 91.00% 88.00%
1600W AC Platinum 87.00% 90.00% 94.00% 91.00%
2000W AC Platinum 89.00% 93.0 0% 94.00% 91.00%