Connecting disk shelf power cables
Prerequisites
Each disk shelf has two power supplies. Connect each power supply to redundant AC power sources, so the loss of one power
supply or one power source does not cause the shelf to power off.
About this task
ES40 shelves have one power cord per power supply for a total of two power cords.
FS25 shelves have one power cord per power supply for a total of two power cords.
DS60 shelves have two power cords per power supply for a total of four power cords.
Steps
1. Plug the power cords into both power supplies on the disk shelf.
2. If the disk shelf has a retention bail, secure the power cord with the retention bail. The bail prevents the power cord from
pulling out of the connector.
3. For ES40 shelves, connect each power cord to redundant power sources in the rack.
Figure 77. ES40 single phase power cabling
Figure 78. ES40 three phase delta power cabling
Figure 79. ES40 three phase WYE power cabling
4. For FS25 shelves, connect each power cord to redundant power sources in the rack.
Figure 80. FS25 single phase power cabling
Figure 81. FS25 three phase delta power cabling
70
Connect Cables and Power On