EasyManua.ls Logo

Dell EMC PowerProtect DD9900 - DD9900 with DS60 Cabling Instructions: DS60 to DS60

Dell EMC PowerProtect DD9900
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 10 DD9900 with DS60 cabling instructions: HA standby node (HA only) (continued)
String
(Loop)
I/O - Port Shelf Port Length
a
3 I/O 7 - Port C LCC A, port 0 of shelf V3.1 3M
3 I/O 3 - Port C LCC B, port 0 of shelf V3.1 3M
4 I/O 7 - Port D FS25 LCC B, port B 3M
4 I/O 3 - Port D FS25 LCC A, port B 3M
a.
Cable lengths shown are designed for Dell EMC racks. Longer cables (up to 5M) can be
used.
Table 11 DD9900 with DS60 cabling instructions: DS60 to DS60
String
(Loop)
First Shelf
Port
Second Shelf Port Length
a
1 LCC A, port 2 of
shelf V1.1
LCC A, port 0 of the next shelf in V1 2M
1 LCC B, port 0 of
shelf V1.1
LCC B, port 2 of the next shelf in V1 2M
2 LCC A, port 2 of
shelf V2.1
LCC A, port 0 of the next shelf in V2 2M
2 LCC B, port 0 of
shelf V2.1
LCC B, port 2 of the next shelf in V2 2M
a.
Cable lengths shown are designed for Dell EMC racks. Longer cables (up to 5M) can be
used.
Connect Cables and Power On
Dell EMC PowerProtect DD9900 System Installation Guide 65

Table of Contents

Related product manuals