Table 10 DD9900 with DS60 cabling instructions: HA standby node (HA only) (continued)
String
(Loop)
I/O - Port Shelf Port Length
a
3 I/O 7 - Port C LCC A, port 0 of shelf V3.1 3M
3 I/O 3 - Port C LCC B, port 0 of shelf V3.1 3M
4 I/O 7 - Port D FS25 LCC B, port B 3M
4 I/O 3 - Port D FS25 LCC A, port B 3M
a.
Cable lengths shown are designed for Dell EMC racks. Longer cables (up to 5M) can be
used.
Table 11 DD9900 with DS60 cabling instructions: DS60 to DS60
String
(Loop)
First Shelf
Port
Second Shelf Port Length
a
1 LCC A, port 2 of
shelf V1.1
LCC A, port 0 of the next shelf in V1 2M
1 LCC B, port 0 of
shelf V1.1
LCC B, port 2 of the next shelf in V1 2M
2 LCC A, port 2 of
shelf V2.1
LCC A, port 0 of the next shelf in V2 2M
2 LCC B, port 0 of
shelf V2.1
LCC B, port 2 of the next shelf in V2 2M
a.
Cable lengths shown are designed for Dell EMC racks. Longer cables (up to 5M) can be
used.
Connect Cables and Power On