6. Under Network Settings, change NIC Selection from Dedicated to one of the following
values:
Table 13 iDRAC NIC to physical port mapping
iDRAC NIC selection Physical network port
LOM1 - [NIC Integrated 1-1-1] Network daughter card port 1
LOM2 - [NIC Integrated 1-2-1] Network daughter card port 2
LOM3 - [NIC Integrated 1-3-1] Network daughter card port 3
LOM4 - [NIC Integrated 1-4-1] Network daughter card port 4
7. Press Esc to return to the previous menu.
8. Exit the BIOS menu and reboot the system to allow the change to take effect.
Enable administrative communication
The serial port and dedicated iDRAC9 dedicated management port at the rear of the system are
the only supported interfaces for console access. Do not connect to the USB and iDRAC direct
micro-USB port on the front of the system.
Use the following settings:
Table 14
Communications settings
Setting Value
Baud rate 115200
Data bits 8
Stop bits 1
Parity None
Flow control None
Emulation VT-100
Establish a serial connection
1. Connect the DB-9 cable to the serial port on the back panel of the system (#2 in the figure
above).
2. Launch a terminal emulation program from your computer and configure the following
communication settings:
Configure System for Use