Parameter Description
• Enclosure Slot Index — Use if drawer argument is not being
used for the command.
• Drawer Slot Index (Index of the drive in the specic drawer)—
Use if drawer argument is used for the command.
• Serial Number—Can be used anytime.
• Drive OS Path—Can be used anytime.
-off
Disable the blink mode for the device by running the command.
-h
Provides more information about the command, description, and
usage.
Command examples
• blink drive -a = 1 -enc = 1 -w = 0 -d = 4
• blink drive -a = 1 -enc = 1 -d = //./PHYSICALDRIVE50 -off
• blink drive -a = 500abcdefgh12345 -enc = 1 -w = 0 -d = 4
• blink drive -d = 500a123456789012
Drive power
Description
Turns o or turns on the drive in the specied enclosure slot number.
Command syntax
shmcli (drive power | drivepower | dp) (-a=<(SAS WWID | AdapterIndex)> -enc=<(WWN | EnclIndex)>
-s=<EnclosureSlotIndex> [-on | -off] | [-h])
Parameters
Table 5. Drive power status
Parameter Description
-a
Species the adapter used for the command. This can be either
SAS WWID or AdapterIndex.
-enc
Species the enclosure used for the command. This can be either
WWN or EnclIndex.
-s
Species the Enclosure Slot Index used for the command. This is
retrieved by the list drives or info drive command.
-on
Turns on the drive on the specied enclosure slot.
-off
Turns o the drive on the specied enclosure slot.
22 CLI reference