Figure 18. Two subnet switch example (IPv4)
Table 3. Two subnet switch example
No. Device IP Address Subnet
1 A0 192.68.10.200 10
2 A1 192.68.11.210 11
3 A2 192.68.10.220 10
4 A3 192.68.11.230 11
5 B0 192.68.10.205 10
6 B1 192.68.11.215 11
7 B2 192.68.10.225 10
8 B3 192.68.11.235 11
9 Switch A N/A N/A
10 Switch B N/A N/A
11 Host server 1, Port 0 192.68.10.20 10
12 Host server 1, Port 1 192.68.11.20 11
13 Host server 2, Port 0 192.68.10.21 10
14 Host server 2, Port 1 192.68.11.21 11
To enable CHAP, see the topic about configuring CHAP in the Dell EMC PowerVault ME4 Series Storage System Administrator’s Guide.
SAS protocol
ME4 Series SAS models use 12 Gb/s host interface protocol and qualified cable options for host connection.
12Gb HD mini-SAS host ports
ME4 Series 12 Gb SAS controller enclosures support two controller modules. The 12 Gb/s SAS controller module provides four SFF-8644
HD mini-SAS host ports. These host ports support data rates up to 12 Gb/s. HD mini-SAS host ports are used for attachment to SAS
hosts directly. The host computer must support SAS and optionally, multipath I/O. Use a qualified cable option when connecting to a host.