Dell EMC PowerVault ME4 Series - Configure FC ports; Configure iSCSI ports

Dell EMC PowerVault ME4 Series
91 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Test notification settings
Perform the following steps to test notifications:
1. Configure your system to receive trap and email notifications.
2. Click Send Test Event. A test notification is sent to each configured trap host and email address.
3. Verify that the test notification reached each configured email address.
NOTE: If there was an error in sending a test notification, event 611 is displayed in the confirmation.
Ports tab—Changing host port settings
You can configure controller host-interface settings for ports except for systems with a 4-port SAS controller module or 10Gbase-T iSCSI
controller module.
To enable the system to communicate with hosts, you must configure the host-interface options on the system.
For a system with a 4-port SAS controller module or 10Gbase-T iSCSI controller module, there are no host-interface options.
For a system with 4-port SFP+ controller modules (CNC), all host ports ship from the factory in Fibre Channel (FC) mode. However, the
ports can be configured as a combination of FC or iSCSI ports. FC ports support use of qualified 16 Gb/s SFP transceivers. You can set
FC ports to auto-negotiate the link speed or to use a specific link speed. iSCSI ports support use of qualified 10 Gb/s SFP transceivers.
For information about setting host parameters such as FC port topology, and the host-port mode, see the Dell EMC PowerVault ME4
Series Storage System CLI Reference Guide.
NOTE:
If the current settings are correct, port configuration is optional.
Configure FC ports
Perform the following steps to configure FC ports:
1. Perform one of the following to access the options in the Ports tab:
In the Home topic, select Action > System Settings, then click Ports.
In the System topic, select Action > System Settings, then click Ports.
In the Welcome panel, select System Settings, and then click the Ports tab
2. From the Host Post Mode list, select FC.
3. From the Port Settings tab, set the port-specific options:
Set the Speed option to the proper value to communicate with the host, or to auto, which auto-negotiates the proper link speed. A
speed mismatch prevents communication between the port and host. Set a speed only if you want to force the port to use a
known speed.
Set The FC Connection Mode to either point-to-point or auto:
point-to-point: Fibre Channel point-to-point.
auto: Automatically sets the mode that is based on the detected connection type.
NOTE:
4. Perform one of the following:
To save your settings and continue configuring your system, click Apply.
To save your settings and close the panel, click Apply and Close.
A confirmation panel is displayed.
5. Click Yes to save your changes. Otherwise, click No.
Configure iSCSI ports
Perform the following steps to configure iSCSI ports:
1. In the Welcome panel, select System Settings, and then click the Notifications tab.
2. From the Host Post Mode list, select iSCSI.
3. From the Port Settings tab, set the port-specific options:
IP Address. For IPv4 or IPv6, the port IP address. For corresponding ports in each controller, assign one port to one subnet and the
other port to a second subnet. Ensure that each iSCSI host port in the storage system is assigned a different IP address. For
example, in a system using IPv4:
36
Perform system and storage setup