1. Open Server Manager.
2. Select Tools > MPIO.
3. Click the Discover Multi-Paths tab.
4. Select DellEMC ME4 in the Device Hardware Id list.
If DellEMC ME4 is not listed in the Device Hardware Id list:
a. Ensure that there is more than one connection to a volume for multipathing.
b. Ensure that Dell EMC ME4 is not already listed in the Devices list on the MPIO Devices tab.
5. Click Add and click Yes to reboot the Windows server.
Format volumes on Windows server
Perform the following steps to format a volume on a Windows server:
1. Open Server Manager.
2. Select Tools > Computer Management.
3. Right-click on Disk Management and select Rescan Disks.
4. Right-click on the new disk and select Online.
5. Right-click on the new disk again select Initialize Disk. The Initialize Disk dialog box opens.
6. Select the partition style for the disk and click OK.
7. Right-click on the unallocated space, select the type of volume to create, and follow the steps in the wizard to create the volume.
Linux hosts
Ensure that the HBAs or network adapters are installed, the drivers are installed, and the latest supported BIOS is installed.
Fibre Channel host server configuration for Linux
The following sections describe how to configure Fibre Channel host servers running Linux:
Prerequisites
Complete the ME Storage Manager guided system and storage setup process.
Refer to the cabling diagrams within this guide before attaching a host to the storage system; careful planning ensures a successful
deployment.
Administrative or privileged user permissions are required to make system-level changes. These steps assume root level access and
that all required software packages are already installed (for example, DM Multipath).
Attach hosts to the storage system
Perform the following steps to attach Fibre Channel hosts to the storage system:
1. Ensure that all HBAs have the latest supported firmware and driversas described on the Dell Support portal . For a list of supported
standard FC HBAs, see the Dell EMC PowerVault ME4 Seriesstorage Matrix on the Dell website. For OEMs, contact your hardware
provider.
2. Use the FC cabling diagrams to cable the host servers either by using switches or attaching them directly to the storage system.
3. Identify Fibre Channel WWNs to connect to the storage system by doing the following:
a) Open a terminal session.
b) Run the ls –l /sys/class/fc_host command.
c) Run the more /sys/class/fc_host/host?/port_name command and replace the ? with the host numbers that are
supplied in the data output.
d) Record the WWN numeric name.
4. If the hosts are connected to the storage system by FC switches, implement zoning to isolate traffic for each HBA. Skip this step if
hosts are directly connected to the storage system.
a) Use the FC switch management interface to create a zone for each server HBA. Each zone must contain only one HBA WWN and
all the storage port WWNs.
b) Repeat for each FC switch.
NOTE:
The ME4 Series storage systems support single initiator/multiple target zones.
46 Perform host setup