Power supplies
The VEP4600 ships with one or two AC power supplies, depending on the conguration. Airow is from the I/O panel to the PSU—the red
indicator is the normal airow direction.
Two PSUs are required for full redundancy, but the platform can operate with a single PSU.
The PSUs are eld replaceable. When running with full redundancy—two power supplies installed and running—you can remove and
replace one PSU without disrupting trac.
CAUTION: To prevent electrical shock, ensure that the VEP4600 is grounded properly. If you do not ground your equipment
correctly, excessive emissions may result. Use a qualied electrician to ensure that the power cables meet your local electrical
requirements.
NOTE: Connect the power supply to the appropriate branch circuit protection as dened by your local electrical codes. Verify
that the remote power source complies with the platform input power specications.
NOTE: If you use a single PSU, install a blank plate in the other PSU slot. Use power supply 2 (PSU2) as the blank-plate slot. You
do not need tools to install the blank plate.
NOTE: ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when
handling the VEP4600 and components.
Topics:
Components
AC power supply installation
Components
PSU LEDs
Figure 13. VEP4600 PSUs
1
PSUs
Solid green—Input is OK.
Flashing yellow (amber)—There is a fault with the PSU.
Flashing green blink at 1Hz—Platform is in a standby/CR state.
5