Figure 55. Installing the heat sink onto the processor
Next steps
1 Install the processor and heat sink module.
2 Install the air shroud.
3 Follow the procedure listed in After working inside your system.
Installing a processor and heat sink module
Prerequisites
CAUTION
: Never remove the heat sink from a processor unless you intend to replace the processor. The heat sink is necessary to
maintain proper thermal conditions.
1 Follow the safety guidelines listed in Safety instructions.
2 If installed, remove the processor/DIMM blank and CPU dust cover.
The procedure to remove the processor/DIMM blank is similar to that of the memory module.
Steps
1 Align the pin 1 indicator of the heat sink to the system board and then place the processor and heat sink module (PHM) on the
processor socket.
CAUTION
: To avoid damaging the ns on the heat sink, do not press down on the heat sink
ns.
NOTE: Ensure that the PHM is held parallel to the system board to prevent damaging the components.
2 Push the blue retention clips inward to allow the heat sink to drop into place.
3 Supporting the heat sink with one hand.
Installing and removing system components
69