Figure 87. Removing non-redundant cabled AC PSU
Next step
1 Installing a non-redundant cabled AC power supply.
Installing a non-redundant cabled AC power supply unit
Prerequisite
1 Follow the safety guidelines listed in Safety instructions.
Steps
1 Unpack the new power supply unit (PSU).
2 Slide the new PSU into the PSU cage until the PSU is fully seated.
3 Using Phillips #2 screwdriver, tighten the screw to secure the PSU to the system.
Figure 88. Installing a non-redundant cabled AC PSU
Next steps
1 Connect all the cable connectors to the system board.
2 If applicable, install the expansion card riser.
3 Install the air shroud.
4 Follow the procedure listed in After working inside your system.
Installing and removing system components