Jumpers and connectors
Topics:
System board jumper settings
System board jumpers and connectors
Disabling forgotten password
System board jumper settings
For information on resetting the password jumper to disable a password, see the Disabling a forgotten password section.
Table 44. System board jumper settings
Jumper Setting Description
PWRD_EN The password reset feature is enabled (pins 24). BIOS local
access is unlocked at the next AC power cycle.
The password reset feature is disabled (pins 46).
NVRAM_CLR
The configuration settings are retained at the next system
boot (pins 35).
The configuration settings are cleared at system boot (pins
13).
Related tasks
Disabling forgotten password on page 200
8