Figure 85. Installing the 4 x 2.5-inch rear drive module
Next steps
1. Connect all the cables to the rear drive module.
2. Install the drives.
3. If removed, install the BOSS S2 module.
4. If removed, install the air shroud.
5. Follow the procedure listed in After working inside your system.
Removing the 2 x 2.5-inch rear drive module
Prerequisites
1. Follow the safety guidelines listed in Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. If required, remove the air shroud.
4. Remove the drives.
5. Disconnect the cables from the rear drive module.
NOTE: Refer cable routing topic for more information.
Steps
1. Using a Phillips #2 screwdriver, loosen the captive screws that secures the rear drive module to the system.
2. Press the blue release tab and holding the edges lift the rear drive module away from the system.