Figure 105. Installing the adapter PERC
3. Insert the adapter PERC in the slot 1 of the system board.
Next steps
1. If removed, install the air shroud.
2. Follow the procedure listed in After working inside the system.
Removing the rear mounting front PERC module
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the drive backplane cover.
4. Remove the air shroud.
5. Remove the cooling fan cage.
6. Disconnect all the cables, observe the cable routing.
Steps
1. Using a Phillips #2 screwdriver, loosen the captive screws on rear mounted front PERC module.
2. Slide the front PERC module to disengage from the connector on the drive backplane.