Figure 75. Installing the processor heat sink module
2. Set the anti-tilt wires to the locked position (outward position), and then using the Torx #T30 screwdriver, tighten the
screws (8 in-lbf) on the heat sink in the order below:
a. In a random order, tighten the first nut three turns.
b. Tighten the nut diagonally opposite to the nut you tighten first.
c. Tighten the nut diagonally opposite to the nut you tighten first.
d. Return to the first nut to tighten it completely.
e. Check all the nuts to ensure they are firmly secured.
Installing and removing system components