24 EMC VNXe3100 Hardware Information Guide
Overview
Table 3 describes the SP status LEDs. The locations in Table 3 are shown in Figure 10 on
page 23.
Table 3 SP LEDs
LED Color State Description
CRU fault
(location 7)
Amber On Fault, lights amber when an internal customer
replaceable unit (CRU) has faulted.
Off No fault or power off
Unsafe to
remove
(location 8)
White On
Do not
remove SP, data could be lost
Off Safe to remove SP
Power
(location 9)
Green On Power on
Off Power off, verify connection
Status/fault
(location 10)
Amber Blinks once
every four
seconds
BIOS running
Blinks once
every
second
POST running
Blinks four
times a
second
Operating system boot started
Blinks
twice a
second
Dump in progress
On SP or Solid State Disk (SSD) fault
Off No fault detected
Blue Blinks once
every four
seconds
Operating system booted
Blinks once
every
second
Operating system driver starting
Blinks four
times a
second
1. Operating system driver started
2. Fault, a system error has occurred, causing some
storage resources to become unavailable. The SP
is not operating and the status LED is blinking
(see Note)
On System not initialized. A management IP address
(static or dynamic) is assigned.