47
Dell EqualLogic PS-M4110 Installation Guide
Setting up a Dedicated Management Port
2.
Connect to the PS-M4110 array using the following racadm command:
racadm server xx connect
3.
Log in to the PS-M4110 array as grpadmin.
4.
Configure a dedicated management port.
The following steps require static IP addresses for management of the array. They must be IP addresses on a
management network (LAN) - not on the SAN. One IP address is required for Group Management and an
additional IP address is required for each array in the group.
These IP addresses must be on the same subnet/network that the CMC is on, or a subnet that has a valid
route to the CMC. The IP addresses must be on a subnet that has access to the subnet that the CMC is on,
but it doesn't have to be the same subnet.
Activate the controller management port(s) using the following CLI commands:
>member select [name of member]
(array1)>eth select 1
(array1 eth_1)>ipaddress [mgmt port ip] netmask [mask]
(array1 eth_1)>up
(array1 eth_1)>exit
(array1)>grpparams
(array1(grpparams))> management-network ipaddress [mgmt group ip]
(array1(grpparams))>exit