EasyManua.ls Logo

Dell PowerConnect B-RX - Syslog Messages

Dell PowerConnect B-RX
1458 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BigIron RX Series Configuration Guide 1299
53-1002253-01
Syslog messages
A
Syslog messages
Table 228 lists all of the Syslog messages. The messages are listed by message level, in the
following order:
Emergencies (none)
Alerts
Critical
Errors
Warnings
Notifications
Informational
Debugging
TABLE 228 Brocade Syslog messages
Message level Message Explanation
Alert Power supply <num>, <location>, failed A power supply has failed.
The <num> is the power supply number.
The <location> describes where the failed
power supply is in the device.
Alert Fan <num>, <location>, failed A fan has failed.
The <num> is the power supply number.
The <location> describes where the failed
power supply is in the device.
Alert Management module at slot <slot-num>
state changed from <module-state> to
<module-state>.
Indicates a state change in a management
module.
The <slot-num> indicates the device slot
containing the module.
The <module-state> can be one of the
following:
active
standby
crashed
coming-up
unknown
Alert Temperature <degrees> C degrees, warning
level <warn-degrees> C degrees, shutdown
level <shutdown-degrees> C degrees
Indicates an overtemperature condition on
the active module.
The <degrees> value indicates the
temperature of the module.
The <warn-degrees> value is the warning
threshold temperature configured for the
module.
The <shutdown-degrees> value is the
shutdown temperature configured for the
module.
Alert <num-modules> modules and 1 power
supply, need more power supply!!
Indicates that the device needs more power
supplies to run the modules in the device.
The <num-modules> parameter indicates the
number of modules in the device.
Alert OSPF Memory Overflow OSPF has run out of memory.