BigIron RX Series Configuration Guide 1299
53-1002253-01
Syslog messages
A
Syslog messages
Table 228 lists all of the Syslog messages. The messages are listed by message level, in the
following order:
• Emergencies (none)
• Alerts
• Critical
• Errors
• Warnings
• Notifications
• Informational
• Debugging
TABLE 228 Brocade Syslog messages
Message level Message Explanation
Alert Power supply <num>, <location>, failed A power supply has failed.
The <num> is the power supply number.
The <location> describes where the failed
power supply is in the device.
Alert Fan <num>, <location>, failed A fan has failed.
The <num> is the power supply number.
The <location> describes where the failed
power supply is in the device.
Alert Management module at slot <slot-num>
state changed from <module-state> to
<module-state>.
Indicates a state change in a management
module.
The <slot-num> indicates the device slot
containing the module.
The <module-state> can be one of the
following:
• active
• standby
• crashed
• coming-up
• unknown
Alert Temperature <degrees> C degrees, warning
level <warn-degrees> C degrees, shutdown
level <shutdown-degrees> C degrees
Indicates an overtemperature condition on
the active module.
The <degrees> value indicates the
temperature of the module.
The <warn-degrees> value is the warning
threshold temperature configured for the
module.
The <shutdown-degrees> value is the
shutdown temperature configured for the
module.
Alert <num-modules> modules and 1 power
supply, need more power supply!!
Indicates that the device needs more power
supplies to run the modules in the device.
The <num-modules> parameter indicates the
number of modules in the device.
Alert OSPF Memory Overflow OSPF has run out of memory.