3.7 Port Commands
3.7.1 set port test (ADMIN)
Synopsys:
set port test port_number [prbs31 on|off|start|stop]
Description:
Configure test mode on a port. Test mode is used to measure link quality and calibrate link tuning parame-
ters.
port_number: downlink port number on which to
enable / disable test mode
prbs31: industry-standard pseudo-random binary sequence for link tuning
- prbs31 on: move the port to test mode
- prbs31 start: initalize prbs31 mechanis
m and start error counting
- prbs31 stop: terminate prbs31 error counting
- prbs31 off: move the port ba
ck to operational mode
Note: After “prbs31 on” and before “prbs31 start”, configure prbs31 on the remote peer.
Example:
& set port test 6 prbs31 on
& # enable prbs31 on remote peer now
& set port test 6 prbs31 start
& show port test 6
port 6 prbs31 on: 0 errors
& set port test 6 prbs31 stop
& set port test 6 prbs31 off
3.7.2 show port link
Synopsys:
show port link [port_number]
Description:
This command displays detailed port information. If an uplink port number is specified
([port_number]), then the command displays information only for this port; otherwise, the com-
mand displays information for all the ports.
The command displays the following information per port:
Port number
Port group identifier and speed: A, B, fo
llowed by the configured speed (10G)
Pass through connection status, may have one
of the following values:
down - either uplink or downlink is not
connected