14 Getting Started With Your System
Wa tta ge
1400 W high line
Voltage
200–240 VAC, 50/60 Hz, 8.6–7.2 A
Heat dissipation
5432 BTU/hr maximum
Maximum inrush current
Under typical line conditions and over
the entire system ambient operating range,
the inrush current may reach 25 A per power
supply for 10 ms or less
Batteries (per system board)
System battery
CR 2032 3.0-V lithium ion coin cell
RAID battery (optional) 3.7 V lithium ion battery pack
Physical
Height 8.7 cm (3.4 in)
Width 44.8 cm (17.6 in)
Depth 75.1 cm (29.6 in)
Weight (maximum configuration) 36.5 kg (80.5 lb)
Weight (empty) 20 kg (44.1 lb)
Environmental
NOTE: For additional information about environmental measurements for specific
system configurations, see www.dell.com/environmental_datasheets.
Temperature
Operating
10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour
NOTE: For altitudes above 2950 feet,
the maximum operating temperature
is derated 1ºF/550 ft.
Storage
–40° to 65°C (–40° to 149°F) with
a maximum temperature gradation
of 20°C per hour
Power (continued)