EasyManua.ls Logo

Dell PowerEdge C6220 - Page 67

Dell PowerEdge C6220
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
67
FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC
Manual\BMC\C6220_BMC_HOM_section1.fm
Table 1-52. Threshold Settings and Converting Formulas (continued)
Sensor
Number
Sensor Name The Converting Formula
Upper non-
recoverable
Upper
critical
Upper
non-
critical
Lower non-
recoverable
Lower
critical
Lower
non-
critical
Temperature
40h MEZZ1 Temp Actual_Reading (degrees C) = Raw_Data - 128
C6 BC B0 8F 97 A0
41h CPU1 Temp Actual_Reading (degrees C) = Raw_Data
5A 50 46 20 25 29
42h CPU2 Temp Actual_Reading (degrees C) = Raw_Data
5A 50 46 20 25 29
43h DIMM ZONE
1 Temp
Actual_Reading (degrees C) = Raw_Data
3C 32 28 17 1A 1E
44h DIMM ZONE
2 Temp
Actual_Reading (degrees C) = Raw_Data
3C 32 28 17 1A 1E
45h PCH Temp Actual_Reading (degrees C) = Raw_Data
5A 50 46 17 1A 1E