EasyManua.ls Logo

Dell PowerEdge M1000e - 10 Gb Ethernet I;O Interoperability

Dell PowerEdge M1000e
135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
setsysinfo
Description Sets the name or location of the chassis.
To run this subcommand, you must have the Administrator privilege.
NOTE: The special characters “ (double quotation mark), ‘ (backward quotation mark), &
(ampersand), and \ (backward slash) are not supported for this subcommand.
Synopsis
racadm setsysinfo -c chassisname|chassislocation <string>
Input
<string> — Indicates a maximum of 64 nonextended ASCII chassis name or location.
-c — Sets the chassis name or location.
Example
racadm setsysinfo -c chassisname "Dell Rack System"
The chassis name was set successfully
racadm setsysinfo -c chassislocation chassislocation2
Sets Chassis location.
sshpkauth
Description Enables you to upload and manage up to 4 dierent SSH public keys for each user. You can upload a key le or
key text, view keys, or delete keys.
This command has three mutually exclusive modes determined by the options — upload, view, and
delete.
To run this subcommand, you must have Congure user privilege.
NOTE:
For DSA keys greater than 2048, use the following racadm command:
racadm -r 192.168.8.14 -u root -p calvin sshpkauth -i svcacct -k 1 -p
0xfff -f dsa_2048.pub
CMC accepts RSA keys up to key strength 4096, but the recommended key strength is 1024.
Synopsis
racadm sshpkauth -i svcacct -k <key_index> -p <privilege> -t <PK_key_text>
racadm sshpkauth -i svcacct -k <key_index> -p <privilege> -f <PK_key_text>
racadm sshpkauth -v -i svcacct -k all|<key_index>
racadm sshpkauth -d -i svcacct -k all|<key_index>
Input
-i <user_index> — Index for the user, it must be svcacct for CMC.
-k [<key_index> | all] — Index to assign the PK key being uploaded. all only works with the -v
or -d options. <key_index> must be between 1 to 6 or all on CMC.
-p <privilege> — Level to give to user for this PK key.
-r <cmcIpAddr>Species the controller’s remote IP address.
-u <username>Species the user name.
-t <PK_Key_Text> — Key text for the SSH Public key.
-f <filename> — File containing the key text to upload.
NOTE: The -f option is not supported on Telnet or SSH or serial RACADM.
-v — View the key text for the index provided.
-d — Delete the key for the index provided.
71

Table of Contents

Other manuals for Dell PowerEdge M1000e

Related product manuals